Product: Pneumatic Gate Valve
Introduction :
The pneumatic gate valve is composed of a linear pneumatic cylinder and a gate valve. Due to its superior material and solid structure, it is widely used in harsh working environments.
Performance Features
1. Pneumatic gate valve can be equipped with electrical or pneumatic limit switches to send information about the status of the valve. Therefore, the use of this valve can achieve remote control, centralized control and automatic control.
2. The cylinder is selected for the manufacture of seamless steel tubes. The inner surface is plated with corrosion-resistant hard chromium and polished.
3. The sealing ring in the cylinder adopts nitrile rubber O -shaped sealing ring, which has reliable sealing performance and is easy to replace during maintenance.
Material of main parts
Valve body/Bonnet/Wedge |
Cast steel, stainless steel |
Sealing surface of valve body and gate |
Hard alloy |
Stem |
stainless steel |
Stud |
35 # steel |
cylinder |
20 # seamless steel pipe |
piston |
Cast aluminum alloy |
Manual nut |
bronze |
Sealing ring |
Spiral wound metal graphite gasket |
Piston ring and collar |
Oil-resistant rubber O-ring |
Major Specification
Valve Size |
DN40-DN700 , 1 1/2 '' -28'' |
Valve Pressure |
PN 0.6 Mpa – 10.0 Mpa, Class 150 – class 600 |
Air Supply |
2.5 bars -8 bars, Max 10 bars |
Stroke |
90mm-1030mm |
Function |
On-off, quick opening and closing, emergency shut-down |
Suitable media |
Water, oil, gas, air, particles, etc |
Working temperature |
-40 ℃ to 450 ℃ |
Ambient temperature |
-20°C to 90°C |
Optional accessories |
solenoid valve, positioner, limit switch, filter, regulator, lubricator, etc |
Structural features
1. This valve is mainly composed of valve body, bonnet, gate, valve stem, sealing ring, double-layer cylinder and its piston, piston rod, baffle as well as buffer mechanism, manual mechanism, pneumatic - manual conversion device and bonnet filling device, etc. composition
2. When the upper piston travels to the upper end of the stroke, the upper echo can be pushed up to send a signal; the lower end of the stroke of the lower piston can be pushed down the lower echo to send a signal, which is used as the simulation of the gate valve opening and closing information in the central operating room Display on the dashboard ;
3. The extension of the upper part of the handwheel indicates the ascent and descent of the lever, which indicates whether the valve's shutter is in the raised state or the lowered state. When the gate valve is closed, the outreach indicator rod is in the low position; otherwise, when the gate valve is fully open, the outreach indicator rod is in the high position. This is the on-site indication of the valve opening and closing status
4. The upper part of the cylinder head is equipped with a pneumatic - manual conversion device. Lift the switch handle clockwise to the " pneumatic " positioning hole for positioning, and the gate valve is in the pneumatic operation state; conversely, lift the switch handle counterclockwise to " manual " for positioning at the hole, the gate valve can be manually operated. The conversion direction of the handle with bevel gear is opposite. When manually operating the gate valve, the handwheel rotation direction is the same as that of the ordinary manual valve, that is, turn clockwise to close, and turn counterclockwise to open. The reverse rotation of the bevel gear.
Installation, use and maintenance
1. Before installing the valve, carefully check whether the model meets the requirements for use.
2. The valve can be installed in any working position, but the convenience of maintenance and operation should be considered.
3. Before the valve is installed, the valve body should be tested for sealing; before the valve is installed, more than three no-load opening and closing tests should be performed. The gate switch of the pneumatic gate valve should be flexible, and various shafts must not be stuck.
4. During the installation process, the dirt in the hole, the sealing surface and the joint surface should be removed , and the connection bolts should be tightened evenly.
5. Sealing test, pneumatic and manual operation test shall be carried out after installation. At the same time, check whether the echo signal can be sent correctly when the valve is fully open or fully closed.
6. When the valve is in use, it is required to fully open and close the gate, and it is not allowed to open the gate valve as a throttle valve to adjust the flow rate. Otherwise, the sealing surface will be damaged under the scouring of the medium flow rate.
7. During the use of the valve, a small amount of lubricant should be added to the inner wall of the cylinder regularly ( 18 months).
8. During the use of the valve, regular inspection and maintenance should be carried out depending on the frequency of its actions. 9. The conversion handle on the pneumatic - manual conversion device is in the manual position, and pneumatic operation is absolutely not allowed .
FAQ:
1. Q: Do you have any certification for pneumatic gate valves?
A: Yes, it is certified by ISO 9001 and SIL Level 3.
2. Q: Can I get one free sample to try in my market?
A: Sorry, such sample should be charged firstly but can be returned after the regular orders .
3, Q: Can you customize our design and logo for Pneumatic gate valves?
A: Yes, we can do ODM and OEM for all customers.
For more questions and answers, please click here
Contact: Zhang Heng (Bill )
Phone: 86 13634285240
Tel: 86 0577 86915200
Email: cspneumatic@hotmail.com